Manual NORDAC SK 1xxE Series SK 140E Æ Electronic motor starter SK 150E Æ Electronic soft starter SK 160E Æ Electronic reversing starter
NORDAC SK 150E 10 Technical modifications observed BU 0100 GB 3.2 Device design 3.2.1 SK 150E-1-O-3D-T125 The
NORDAC SK 150E BU 0100 GB Technical Modifications Reserved 11 3.3 Electrical connection Power cable: The system connection shall be performed w
NORDAC SK 150E 12 Technical modifications observed BU 0100 GB 3.4 Display and settings The following controls are available for the SK 150E:
NORDAC SK 150E BU 0100 GB Technical Modifications Reserved 13 3.4.2 Setting the potentiometers and dip switches With the electronic soft starter
NORDAC SK 150E 14 Technical modifications observed BU 0100 GB P 1 P 2 P 3 P 4 P 2 Operating mode "01" These and the subsequent oper
NORDAC SK 150E BU 0100 GB Technical Modifications Reserved 15 The following table provides an overview of all dip switches and potentiometers as
NORDAC SK 150E 16 Technical modifications observed BU 0100 GB DIP switches The 4 existing dip switches are used to set the operating mode and t
NORDAC SK 150E BU 0100 GB Technical Modifications Reserved 17 Potentiometers With the 4 potentiometers, the user can adjust the different times a
NORDAC SK 160E 18 Technical modifications observed BU 0100 GB 4 Electronic Reversing Starter SK 160E 4.1 Principle of function With the SK
NORDAC SK 160E BU 0100 GB Technical Modifications Reserved 19 4.2 Device design The reverse starter SK 160E is available in the following v
Table of content 2 BU 0100 GB 1 General description ...
NORDAC SK 160E 20 Technical modifications observed BU 0100 GB 4.2.1 SK 160E-1-O(-C)-3D-T125 The SK 160E-1-O(-C)-3D-T125 is motor reverse star
NORDAC SK 160E BU 0100 GB Technical Modifications Reserved 21 4.3 Electrical connection Power cable: The system connection shall be performed
NORDAC SK 160E 22 Technical modifications observed BU 0100 GB 4.4 Display and settings The following controls are available for the SK 160E:
NORDAC SK 160E BU 0100 GB Technical Modifications Reserved 23 4.4.2 Rotary dip code switches for locking time With the help of two 10-step rotar
NORDAC SK 160E 24 Technical modifications observed BU 0100 GB 5 Options / Accessories SK 1xxE 5.1 SK 1xxE on motor with electromechanical
Options / Accessories SK 1xxE BU 0100 GB Technical Modifications Reserved 25 5.2 Wall-mounting kit An installation in close proximity to the m
Options / Accessories SK 1xxE 26 Technical modifications observed BU 0100 GB 5.3 System plug for power input or motor output All series SK 1
Options / Accessories SK 1xxE BU 0100 GB Technical Modifications Reserved 27 5.4 Signal plug M12 for control signals A signal plug M12 can be
Technical data SK 1xxE 28 Technical modifications observed BU 0100 GB 5.5 AS interface bus connection The AS1 module (4 inputs / 4 outputs)
Options / Accessories SK 1xxE BU 0100 GB Technical Modifications Reserved 29 5.5.1 AS interface as additional assembly An AS interface can be
NORDAC SK 1xxE BU 0100 GB Technical Modifications Reserved 3 1 General description The product series NORDAC SK 1xxE constitutes a motor or wal
Technical data SK 1xxE 30 Technical modifications observed BU 0100 GB 6 Technical data / Dimensions Technical data Function Specification
Options / Accessories SK 1xxE BU 0100 GB Technical Modifications Reserved 31 Dimensions Motor size SK 1xxE SK 140E SK 150E / SK 160E g o g1
Maintenance and service notes SK 1xxE 32 Technical modifications observed BU 0100 GB 7 Maintenance and service notes NORDAC SK 1xxE are main
Index BU 0100 GB Technical Modifications Reserved 33 8 Index A accessories ... 24 AS inter
Agencies and branch offices 34 BU 0100 GB 9 Agencies and branch offices N O R D Branch offices worldwide: Brazil / Brasilien NORD Motoredutor
Agencies and branch offices BU 0100 GB Technical Modifications Reserved 35 N O R D Branch offices in Europe: Austria / Österreich Getriebebau NORD
Mat. No. 608 1002 / 2307 NORD Offices in Germany Getriebebau NORD GmbH & Co. KG Rudolf- Diesel- Str. 1 ⋅ 22941 Bargteheide Telephone 04532 /
NORDAC SK 1xxE 4 Technical modifications observed BU 0100 GB SAFETY NOTES Safe operation of the device requires that it is mounted and ma
NORDAC SK 140E BU 0100 GB Technical Modifications Reserved 5 2 Electronic Motor Starter SK 140E 2.1 Principle of function The SK 140E enables
NORDAC SK 140E 6 Technical modifications observed BU 0100 GB 2.2 Device design 2.2.1 SK 140E-1-O The SK 140E-1-O (Mat. No. 27510
NORDAC SK 140E BU 0100 GB Technical Modifications Reserved 7 2.3 Electrical connection Power cable: The system connection shall be performed wi
NORDAC SK 140E 8 Technical modifications observed BU 0100 GB 2.4 Display and settings The following controls are available for the SK 140E:
NORDAC SK 150E BU 0100 GB Technical Modifications Reserved 9 3 Electronic Soft Starter SK 150E 3.1 Principle of function The SK 150E allows a