Technical Information / Datasheet
Level adapter PCB HTL - HTL A+/- B+/-
V1.0 Erstausgabe / first issue 4813 Rck TI 18552095 GB
version reason for change(s) issue name document speech
Pos: 2 /T echni s che Infor ma tio nen/ Zu beh ör/Pl ati ne_P egel w andl er_C on tel ectg eb er/Pl ati ne P egel an pass ung HT L - HT L A+/- B+/- / 18 5520 95 / Basi si nfor mati on en [ - HTL -HT L+/-] @ 4\mod_1385464912683_388.docx @ 106965 @ 555 @ 1
Level adapter PCB HTL – HTL A+/- B+/-
Part number: 18 552 095
Level adapter HTL – HTL A+/- B+/-
NOTICE
Validity of the documents
This document is only valid in combination with the operating instructions for the relevant drive unit. All of the
information that is relevant for a safe start-
up of this module and the drive unit is only available under these
conditions.
Scope of delivery
1 x Module PCB, lacquered
Accessories required
1 x Mounting kit
OBW MOUNTING KIT
PCB 185520xxx
(Part No. 18552160)
Usage area
The module, which is intended for installation in the motor terminal box, is used to convert HTL or TTL
signals into complementary HTL signals. With this form of signal, the probability of errors in data
transmission is considerably reduced. Use of this module is recommended for cable lengths in excess
of 30 m.
Technical data
Module
Ambient temperature -25°C … +75 °C Weight 20 g
Protection class IP00 Dimensions [mm] L x W x H: 46 x 35 x 22
Electrical data
Electrical connection Spring terminals Cross-section 20-16 AWG
Input voltage 10 … 30 V DC Connection terminals (0.5 – 1.5 mm
)
Input level "0" ≤ 0.8 V Power consumption 10 mA (own consumption)
Input level "1" ≥ 2.4 V Max. frequency 100 kHz
Max. output voltage = Input voltage Max. cable length 500 m at 20 kHz
Typical output current: 100 mA
dynamic: 200 mA
Kommentare zu diesen Handbüchern